Arq. bras. cardiol ; 112(4): 410-421, Apr. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1001291

RESUMO

Abstract Background: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias and normal ventricular function requiring heart rate correction alone. Objective: To assess the safety, efficacy, and effects of LV pacing using an active-fixation coronary sinus lead in comparison with RV pacing, in patients eligible for conventional pacemaker (PM) implantation. Methods: Randomized, controlled, and single-blinded clinical trial in adult patients submitted to PM implantation due to bradyarrhythmias and systolic ventricular function ≥ 0.40. Randomization (RV vs. LV) occurred before PM implantation. The main results of the study were procedural success, safety, and efficacy. Secondary results were clinical and echocardiographic changes. Chi-squared test, Fisher's exact test and Student's t-test were used, considering a significance level of 5%. Results: From June 2012 to January 2014, 91 patients were included, 36 in the RV Group and 55 in the LV Group. Baseline characteristics of patients in both groups were similar. PM implantation was performed successfully and without any complications in all patients in the RV group. Of the 55 patients initially allocated into the LV group, active-fixation coronary sinus lead implantation was not possible in 20 (36.4%) patients. The most frequent complication was phrenic nerve stimulation, detected in 9 (25.7%) patients in the LV group. During the follow-up period, there were no hospitalizations due to heart failure. Reductions of more than 10% in left ventricular ejection fraction were observed in 23.5% of patients in the RV group and 20.6% of those in the LV group (p = 0.767). Tissue Doppler analysis showed that 91.2% of subjects in the RV group and 68.8% of those in the LV group had interventricular dyssynchrony (p = 0.022). Conclusion: The procedural success rate of LV implant was low, and the safety of the procedure was influenced mainly by the high rate of phrenic nerve stimulation in the postoperative period.


Resumo Fundamento: Considerando-se os potenciais efeitos deletérios da estimulação do ventrículo direito (VD), a hipótese desse estudo é que a estimulação unifocal ventricular esquerda pelo seio coronário é segura e pode proporcionar melhores benefícios clínicos e ecocardiográficos aos pacientes com bradiarritmias que apresentam função ventricular normal, necessitando apenas da correção da frequência cardíaca. Objetivos: Avaliar a segurança, a eficácia e os efeitos da estimulação do ventrículo esquerdo (VE), utilizando um cabo-eletrodo com fixação ativa, em comparação à estimulação do VD. Métodos: Estudo clínico, randomizado, simples-cego em pacientes adultos com indicação de marca-passo (MP) devido a bradiarritmias e função ventricular sistólica ≥ 0,40. A randomização aleatória (VD vs VE) ocorreu antes do procedimento. Os desfechos primários do estudo foram: o sucesso, a segurança e a eficácia do procedimento proposto. Os desfechos secundários foram: a evolução clínica e alterações ecocardiográficas. Empregou-se os testes Qui-quadrado, Exato de Fisher e t de Student, com nível de significância de 5%. Resultados: De junho de 2012 a janeiro de 2014 foram incluídos 91 pacientes, sendo 36 no grupo VD e 55 no grupo VE. As características basais dos pacientes dos dois grupos foram similares. O implante de MP foi realizado com sucesso e sem nenhuma intercorrência em todos os pacientes do grupo VD. Dos 55 pacientes inicialmente alocados para o grupo VE, o implante do cabo-eletrodo em veias coronárias não foi possível em 20 (36,4%) pacientes. Dentre os 35 pacientes que permaneceram com o cabo-eletrodo no VE, a estimulação frênica foi a complicação mais frequente e foi detectada em 9 (25,7%) pacientes. Na fase de seguimento clínico, não houve hospitalizações por insuficiência cardíaca. Reduções superiores a 10% na fração de ejeção do VE foram observadas em 23,5% dos pacientes do grupo VD e em 20,6% dos pacientes do grupo VE (p = 0,767). A análise feita pelo Doppler tecidual mostrou que 91,2% dos indivíduos do grupo VD e 68,8% dos do grupo VE apresentaram dissincronia interventricular (p = 0,022). Conclusões: A taxa de sucesso do implante no VE foi baixa e a segurança do procedimento foi influenciada, principalmente, pela alta taxa de estimulação frênica no pós-operatório.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Marca-Passo Artificial/efeitos adversos , Bradicardia/terapia , Estimulação Cardíaca Artificial/métodos , Ventrículos do Coração/fisiopatologia , Volume Sistólico , Bradicardia/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Método Simples-Cego , Reprodutibilidade dos Testes , Resultado do Tratamento , Implantação de Prótese/métodos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia
2.
Arq. bras. cardiol ; 107(3): 245-256, Sept. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-796031

RESUMO

Abstract Background: Complications after surgical procedures in patients with cardiac implantable electronic devices (CIED) are an emerging problem due to an increasing number of such procedures and aging of the population, which consequently increases the frequency of comorbidities. Objective: To identify the rates of postoperative complications, mortality, and hospital readmissions, and evaluate the risk factors for the occurrence of these events. Methods: Prospective and unicentric study that included all individuals undergoing CIED surgical procedures from February to August 2011. The patients were distributed by type of procedure into the following groups: initial implantations (cohort 1), generator exchange (cohort 2), and lead-related procedures (cohort 3). The outcomes were evaluated by an independent committee. Univariate and multivariate analyses assessed the risk factors, and the Kaplan-Meier method was used for survival analysis. Results: A total of 713 patients were included in the study and distributed as follows: 333 in cohort 1, 304 in cohort 2, and 76 in cohort 3. Postoperative complications were detected in 7.5%, 1.6%, and 11.8% of the patients in cohorts 1, 2, and 3, respectively (p = 0.014). During a 6-month follow-up, there were 58 (8.1%) deaths and 75 (10.5%) hospital readmissions. Predictors of hospital readmission included the use of implantable cardioverter-defibrillators (odds ratio [OR] = 4.2), functional class III­-IV (OR = 1.8), and warfarin administration (OR = 1.9). Predictors of mortality included age over 80 years (OR = 2.4), ventricular dysfunction (OR = 2.2), functional class III-IV (OR = 3.3), and warfarin administration (OR = 2.3). Conclusions: Postoperative complications, hospital readmissions, and deaths occurred frequently and were strongly related to the type of procedure performed, type of CIED, and severity of the patient's underlying heart disease.


Resumo Fundamento: Complicações após procedimentos cirúrgicos em portadores de dispositivos cardíacos eletrônicos implantáveis (DCEI) são um problema emergente devido ao aumento crescente na taxa destes procedimentos e ao envelhecimento da população, com consequente aumento de comorbidades. Objetivos: Identificar as taxas de complicações pós-operatórias, mortalidade e readmissão hospitalar, e pesquisar fatores de risco para a ocorrência desses eventos. Métodos: Registro prospectivo e unicêntrico que incluiu todos os indivíduos submetidos a procedimentos cirúrgicos em DCEI no período de fevereiro a agosto de 2011. Os pacientes foram distribuídos por tipos de procedimento nos seguintes grupos: implantes iniciais (coorte 1), troca de gerador (coorte 2) e procedimentos em cabos-eletrodos (coorte 3). Os desfechos foram avaliados por um comitê independente. Empregou-se a análise univariada e multivariada para a pesquisa de fatores de risco e o método de Kaplan-Meier para análise de sobrevida. Resultados: Foram incluídos 713 pacientes, sendo 333, 304 e 76 distribuídos nas coortes 1, 2 e 3, respectivamente. Complicações pós-operatórias foram detectadas em 7,5%, 1,6% e 11,8% dos pacientes nas coortes 1, 2 e 3, respectivamente (p = 0,014). Durante os 6 meses de seguimento, houve 58 (8,1%) óbitos e 75 (10,5%) readmissões hospitalares. Preditores de readmissão hospitalar incluíram o uso de cardioversor-desfibrilador implantável ( odds ratio [OR] = 4,2), classe funcional III-IV (OR = 1,8) e uso de warfarina (OR = 1,9). Preditores de mortalidade incluíram idade acima de 80 anos (OR = 2,4), disfunção ventricular (OR = 2,2), classe funcional III-IV (OR = 3,3) e uso de warfarina (OR = 2,3). Conclusões: Complicações pós-operatórias, readmissões hospitalares e óbitos foram frequentes. Esses eventos estiveram fortemente relacionados ao tipo de procedimento realizado, tipo de DCEI e gravidade da doença cardíaca do paciente.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Lactente , Pré-Escolar , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Marca-Passo Artificial/efeitos adversos , Readmissão do Paciente/estatística & dados numéricos , Complicações Pós-Operatórias/etiologia , Desfibriladores Implantáveis/efeitos adversos , Terapia de Ressincronização Cardíaca/efeitos adversos , Cardiopatias/cirurgia , Complicações Pós-Operatórias/mortalidade , Reoperação/estatística & dados numéricos , Volume Sistólico , Fatores de Tempo , Modelos Logísticos , Estudos Prospectivos , Fatores de Risco , Fatores Etários , Medição de Risco , Estimativa de Kaplan-Meier , Terapia de Ressincronização Cardíaca/mortalidade , Cardiopatias/mortalidade
3.
In. Kalil Filho, Roberto; Fuster, Valetim; Albuquerque, Cícero Piva de. Medicina cardiovascular reduzindo o impacto das doenças / Cardiovascular medicine reducing the impact of diseases. São Paulo, Atheneu, 2016. p.955-986.
Monografia em Português | LILACS | ID: biblio-971577
4.
Arq. bras. cardiol ; 105(5): 493-502, Nov. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-765001

RESUMO

AbstractBackground:The recording of arrhythmic events (AE) in renal transplant candidates (RTCs) undergoing dialysis is limited by conventional electrocardiography. However, continuous cardiac rhythm monitoring seems to be more appropriate due to automatic detection of arrhythmia, but this method has not been used.Objective:We aimed to investigate the incidence and predictors of AE in RTCs using an implantable loop recorder (ILR).Methods:A prospective observational study conducted from June 2009 to January 2011 included 100 consecutive ambulatory RTCs who underwent ILR and were followed-up for at least 1 year. Multivariate logistic regression was applied to define predictors of AE.Results:During a mean follow-up of 424 ± 127 days, AE could be detected in 98% of patients, and 92% had more than one type of arrhythmia, with most considered potentially not serious. Sustained atrial tachycardia and atrial fibrillation occurred in 7% and 13% of patients, respectively, and bradyarrhythmia and non-sustained or sustained ventricular tachycardia (VT) occurred in 25% and 57%, respectively. There were 18 deaths, of which 7 were sudden cardiac events: 3 bradyarrhythmias, 1 ventricular fibrillation, 1 myocardial infarction, and 2 undetermined. The presence of a long QTc (odds ratio [OR] = 7.28; 95% confidence interval [CI], 2.01–26.35; p = 0.002), and the duration of the PR interval (OR = 1.05; 95% CI, 1.02–1.08; p < 0.001) were independently associated with bradyarrhythmias. Left ventricular dilatation (LVD) was independently associated with non-sustained VT (OR = 2.83; 95% CI, 1.01–7.96; p = 0.041).Conclusions:In medium-term follow-up of RTCs, ILR helped detect a high incidence of AE, most of which did not have clinical relevance. The PR interval and presence of long QTc were predictive of bradyarrhythmias, whereas LVD was predictive of non-sustained VT.


ResumoFundamento:A documentação de eventos arrítmicos (EA) em candidatos a transplante renal (CTR) submetidos à diálise é limitada pelo registro de eletrocardiograma convencional. Um monitoramento contínuo do ritmo cardíaco parece ser o procedimento mais adequado para a detecção automática de arritmia, contudo esse método não foi explorado anteriormente.Objetivo:O objetivo deste estudo foi investigar a incidência e os preditores de EA em CTR usando um gravador de eventos implantável, do inglês, “loop recorder implantável” (ILR).Métodos:Um estudo prospectivo observacional foi conduzido entre Junho/2009 a Janeiro/2011. Cem CTR ambulatoriais consecutivos foram submetidos ao ILR e acompanhados pelo menos por um ano. Uma regressão logística multivariada foi aplicada para definir os preditores de EA.Resultados:Durante o tempo médio de acompanhamento de 424 ± 127 dias, EA foram detectados em 98% dos pacientes, sendo que 92% deles tinham mais de um tipo de arritmia, a maioria não considerada potencialmente séria. Taquicardia atrial sustentada e fibrilação atrial ocorreram respectivamente em 7% e 13% dos pacientes; bradiarritmia em 25% e taquicardia ventricular (TV) não-sustentada ou sustentada em 57%. Ocorreram 18 óbitos, 7 por morte cardíaca súbita, 3 por bradiarritmias, 1 por fibrilação ventricular, 1 por infarto do miocárdio e 2 óbitos devido à causas desconhecidas. A presença de QTc longo (Razão de Probabilidade [RP] = 7,28; intervalo de confiança de 95% [IC] 2,01-26,35; p = 0,002) e duração do intervalo PR (RP = 1,05; IC 95%: 1,02-1,08; p < 0,001) foram associados independentemente a bradiarritmias. A dilatação ventricular esquerda (DVE) foi independentemente associada à TV não-sustentada (RP = 2,83; IC 95%: 1,01-7,96; p = 0,041).Conclusões:Em acompanhamento de médio prazo de CTR, o ILR detectou uma alta incidência de EA, a maioria sem relevância clínica. O intervalo PR e a presença de QTc longo foram preditivos de bradiarritmias e DVE de TV não‑sustentada.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/diagnóstico , Eletrocardiografia Ambulatorial/instrumentação , Transplante de Rim , Arritmias Cardíacas/fisiopatologia , Desenho de Equipamento , Eletrocardiografia Ambulatorial/métodos , Valor Preditivo dos Testes , Estudos Prospectivos , Diálise Renal , Medição de Risco , Fatores de Tempo
5.
Clinics ; 68(7): 986-991, jul. 2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-680714

RESUMO

OBJECTIVES: Few studies have evaluated cardiac electrical activation dynamics after cardiac resynchronization therapy. Although this procedure reduces morbidity and mortality in heart failure patients, many approaches attempting to identify the responders have shown that 30% of patients do not attain clinical or functional improvement. This study sought to quantify and characterize the effect of resynchronization therapy on the ventricular electrical activation of patients using body surface potential mapping, a noninvasive tool. METHODS: This retrospective study included 91 resynchronization patients with a mean age of 61 years, left ventricle ejection fraction of 28%, mean QRS duration of 182 ms, and functional class III/IV (78%/22%); the patients underwent 87-lead body surface mapping with the resynchronization device on and off. Thirty-six patients were excluded. Body surface isochronal maps produced 87 maximal/mean global ventricular activation times with three regions identified. The regional activation times for right and left ventricles and their inter-regional right-to-left ventricle gradients were calculated from these results and analyzed. The Mann-Whitney U-test and Kruskall-Wallis test were used for comparisons, with the level of significance set at p≤0.05. RESULTS: During intrinsic rhythms, regional ventricular activation times were significantly different (54.5 ms vs. 95.9 ms in the right and left ventricle regions, respectively). Regarding cardiac resynchronization, the maximal global value was significantly reduced (138 ms to 131 ms), and a downward variation of 19.4% in regional-left and an upward variation of 44.8% in regional-right ventricular activation times resulted in a significantly reduced inter-regional gradient (43.8 ms to 17 ms). CONCLUSIONS: Body surface potential mapping in resynchronization patients yielded electrical ventricular ...


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mapeamento Potencial de Superfície Corporal/métodos , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Bloqueio de Ramo/fisiopatologia , Terapia por Estimulação Elétrica , Insuficiência Cardíaca/fisiopatologia , Valores de Referência , Estudos Retrospectivos , Estatísticas não Paramétricas , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia
6.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 26(1): 33-38, jan.-mar. 2013.
Artigo em Português | LILACS | ID: lil-682805

RESUMO

Os efeitos da terapia de ressincronização cardíaca (TRC) em pacientes com cardiomiopatiaisquêmica (CMI) e dilatada (CMD) são bem conhecidos. Entretanto, faltam evidências científicas da TRC nacardiomiopatia chagásica crônica (CCC). Objetivo: avaliar o comportamento clínico de pacientes submetidos àTRC, considerando a importância da CCC. Método: no período de janeiro de 2005 a dezembro de 2007 foramincluídos 343 pacientes em seguimento clínico na Unidade de Estimulação Cardíaca do Instituto do Coração,submetidos a intervenção cirúrgica relacionada à TRC. A análise estatística de previsores de mortalidade foirealizada por regressão logística com seleção stepwise, incluindo variáveis com p<0,1 na análise univariada. Asvariáveis estudadas foram: idade, gênero, classe funcional (CF) da New York Heart Association, cardiopatia, tipode bloqueio de ramo, parâmetros ecocardiográficos, medicações em uso e óbito. Resultados: foram selecionados343 pacientes, 65% do sexo masculino, com idade média de 59,7 ± 12,3 anos e seguimento médio de 4,2 ± 2,7anos após a TRC. A CF pré-implante foi II em 18,3%, III em 64,5% e IV em 17,3%. A fração de ejeção média doventrículo esquerdo foi de 27,66 ± 8,99. A cardiopatia de base distribuiu-se em: CMD em 35%; CMI em 29,4%;CCC em 22,4% e outras etiologias em 13,1%. A taxa de melhora da classe funcional após a TRC foi semelhante,independente da cardiopatia, mas a CCC mostrou pior prognóstico (odds ratio=3,03; IC 95%, 1,15-7,97, p<0,001).Conclusão: pacientes com CCC submetidos à TRC apresentam melhora sintomática, porém o risco de óbito é trêsvezes maior em comparação com as outras cardiopatias.


The effects of cardiac resynchronization therapy (CRT) in patients with ischemic (ICM) and dilated(DCM) cardiomyopathy are known. In chronic chagasic cardiomyopathy (CCC), scientific evidence is lacking.Objective: To evaluate the clinical response of patients undergoing CRT, considering the importance of theCCC. Methods: From January 2005 to December 2007, we included 343 patients in clinical follow-up in CardiacPacing Unit of Heart Institute, who underwent surgery related to CRT. Statistical analysis of mortality predictorswas performed using logistic regression with stepwise selection, including variables with P<0.1 in the univariateanalysis. The variables studied were age, gender, functional class of New York Heart Association, etiology of heartdisease, type of bundle branch block, echocardiographic parameters, medications and death. Results: The studyenrolled 343 patients, 65% male, mean age 59.7 ± 12.3 years, with a mean follow-up after CRT of 4.2 ± 2.7 years. The functional class before implant was II, III and IV in 18.3%, 64.5% and 17.3%, respectively. The mean ejectionfraction of the left ventricle was 27.66 ± 8.99. The underlying heart disease was DMC, ICM, CCC and othercauses in 35%, 29.4%, 22.4% and 13.1%, respectively. The rate of improvement in functional class after CRT wassimilar, independent of heart disease etiology, but the CCC showed the worst prognosis (Odds ratio=3.03; 95%CI 1.15-7.97, P<0.001). Conclusion: Patients with CCC undergoing CRT show symptomatic improvement, butthe risk of death is three times higher, compared with other heart diseases.


Los efectos de la terapia de resincronización cardiaca (TRC) en pacientes con miocardiopatía isquémica(MCI) y dilatada (MCD) son conocidos. En la miocardiopatía chagásica crónica (MCC), sin embargo, faltanevidencias científicas. Objetivo: Evaluar el comportamiento clínico de pacientes sometidos a la TRC, considerándosela importancia de la MCC. Métodos: En el período de enero de 2005 a diciembre de 2007, fueron incluidos 343pacientes en seguimiento clínico en la Unidad de Estimulación Cardiaca del Instituto del Corazón, sometidos ala intervención quirúrgica relacionada a la TRC. El análisis estadístico de predictores de mortalidad fue llevado acabo por regresión logística con selección stepwise, incluyéndose variables con p<0,1 en el análisis univariado. Lasvariables estudiadas fueron: edad, género, clase funcional (CF) de la New York Heart Association, cardiopatía, tipode bloqueo de rama, parámetros ecocardiográficos, fármacos en uso y defunción. Resultados: Fueron seleccionados343 pacientes, el 65% del sexo masculino, edad media de 59,7 ± 12,3 años, con seguimiento medio tras la TRC de4,2 ± 2,7 años. La CF pre implante fue II en el 18,3%, III en el 64,5% y IV en el 17,3%. La fracción de eyección deventrículo izquierdo media fue de 27,66 ± 8,99. La cardiopatía de base se distribuyó en: MCD en el 35%; MCI enel 29,4%; MCC en el 22,4% y otras etiologías en el 13,1%. El índice de mejora de clase funcional tras la TRC fuesemejante, independientemente de la cardiopatía, pero la MCC mostró peor pronóstico (Odds Ratio=3,03 IC95%1,15-7,97, p<0,001). Conclusión: Pacientes con MCC sometidos a la TRC presentan mejora sintomática, sin embargo,riesgo de fallecimiento tres veces mayor, en comparación con las otras cardiopatías.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Terapia de Ressincronização Cardíaca , Cardiomiopatia Chagásica/terapia , Doença de Chagas/história , Estudos Retrospectivos
7.
Arq. bras. cardiol ; 88(1): 1-7, jan. 2007. tab, graf
Artigo em Português | LILACS | ID: lil-443635

RESUMO

OBJETIVO: Avaliar os efeitos da estimulação atrial otimizada (EAO) (estimulação duplo-sítio atrial, freqüência acima da intrínseca e algoritmo funcional específico) e uso de atenolol, na prevenção da fibrilação atrial (FA) recorrente. Desfecho primário: quantificar a taxa de episódios de FA. Desfechos secundários: qualidade de vida, avaliação de sintomas específicos cardiovasculares, taxa de internações hospitalares, taxa de cardioversões elétricas e farmacológicas e eventos cardíacos adversos. MÉTODOS: Vinte e sete pacientes com FA paroxística recorrente e doença do nó sinusal foram submetidos ao implante de marcapasso duplo-sítio atrial e ventricular e iniciaram com atenolol 100 mg/dia, a seguir foram randomizados em dois grupos, grupo I (3 meses iniciais com EAO e algoritmo especifico ligado e mais 3 com o mesmo desligado) e grupo II (seqüência inversa do grupo I). O modo de estimulação foi DDDR e após 3 meses, foram submetidos à avaliação clínica e eletrônica do sistema de estimulação - mudança automática de modo (AMS), Holter de 24 horas, ecocardiograma e questionário SF-36. Em seguida, foram cruzados e após 6 meses, nova avaliação. RESULTADOS: Pacientes com EAO, quando comparados ao grupo com algoritmo desligado, apresentaram menores taxas de: FA/semana (p<0,001), ativações do AMS (p<0,01), hospitalizações (p<0,001), cardioversões (p<0,001), além de melhores índices dos componentes físico e mental da qualidade de vida. CONCLUSÃO: A terapêutica híbrida, EAO associada ao uso de atenolol, reduziu a taxa de recorrência de FA e proporcionou melhora clínico funcional de pacientes com bradiarritmias sintomáticas.


OBJECTIVE: Evaluate the effects of optimized atrial stimulation - OAS (dual-site atrial pacing, heart rate above the intrinsic rate, and specific functional algorithm), and the use of atenolol in preventing recurrent atrial fibrillation (AF). Primary endpoint: to quantify the rate of AF episodes. Secondary endpoints: assessment of quality of life, specific cardiovascular symptoms, rate of hospital admissions, rate of electrical and pharmacological cardioversions, and adverse cardiac events. METHODS: Twenty-five patients with recurrent episodes of paroxysmal AF and sinus node disease had dual-site atrial and ventricular pacemakers implanted, and were started on atenolol, 100 mg/day. Next, they were randomized to two groups: GROUP I: first three months with OAS and the specific pacing algorithm (DAO) turned on, and three more months with the algorithm off. GROUP II: the inverse sequence to GROUP I. The pacing mode chosen was DDDR, and after three months patients underwent clinical and electronic evaluations of the stimulation system by: automatic mode switch (AMS), 24-hour Holter monitoring, Doppler echocardiogram, and SF-36 questionnaire. Following, a crossover comparison took place, and a new assessment was performed six months later. RESULTS: When compared to the group with the algorithm turned off, OAS patients had lower rates of: AF/week (p < 0.001); AMS activations (p < 0.01); hospitalizations (p < 0.001); cardioversions (p < 0.001), and higher scores on the physical and mental components of quality of life. CONCLUSION: The hybrid therapy adopted, OAS associated with the use of atenolol, reduced the rate of recurrent AF and improved the clinical-functional status of patients with symptomatic bradyarrhythmias.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Antiarrítmicos/uso terapêutico , Atenolol/uso terapêutico , Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial , Síndrome do Nó Sinusal/terapia , Algoritmos , Terapia Combinada , Estudos Cross-Over , Cardioversão Elétrica , Seguimentos , Estudos Prospectivos , Qualidade de Vida , Recidiva/prevenção & controle , Método Simples-Cego , Fatores de Tempo
8.
Rev. bras. cir. cardiovasc ; 20(2): 123-128, abr.-jun. 2005. graf
Artigo em Português | LILACS | ID: lil-413756

RESUMO

OBJETIVO: A estimulação cardíaca permanente melhora a sobrevida de crianças com bradicardia congênita ou adquirida, embora a mortalidade após o implante de marcapasso permaneça relativamente alta. O objetivo deste estudo foi avaliar os resultados em longo prazo de crianças submetidas a implante de marcapasso endocárdico pela veia femoral, incluindo a identificação de fatores de risco associados à mortalidade. MÉTODO: De 1981 a 2000, 99 pacientes variando em idade de um dia a 13 anos (4,1 ± 3,6 com mediana = 3 anos) foram submetidos a implante de marcapasso permanente pela via femoral devido a bradicardia de origem congênita (39,4 por cento), pós-cirúrgica (54,5 por cento) ou adquirida não cirurgicamente (6,1 por cento). RESULTADOS: Ao final de 7,1 ± 5,3 anos (708,3 pacientes-anos) de seguimento, 18 (18,2 por cento) pacientes haviam morrido. A sobrevida atuarial foi de 85 por cento, 79,5 por cento, e 74,2 por cento, aos cinco, 10, e 15 anos, respectivamente. Os fatores independentes de mortalidade identificados pela análise proporcional de Cox foram: menor idade ao implante (p = 0,028), presença de anomalias cardíacas não corrigidas ou presença de próteses intracardíacas (p = 0,0001) e evidências radiográficas de cardiomegalia (p = 0,035). CONCLUSÕES: A estimulação cardíaca endocárdica permanente pela via femoral apresenta expectativa de sobrevida comparável a outras técnicas, com baixas taxas de complicações devidas ao implante de marcapasso. A sobrevida em longo prazo foi limitada pela menor idade e dilatação cardíaca no momento do implante, assim como pela presença de defeitos cardíacos sem correção ou de próteses valvares.


Assuntos
Humanos , Criança , Bradicardia/congênito , Estimulação Cardíaca Artificial , Mortalidade Infantil , Bloqueio Cardíaco , Avaliação de Resultados em Cuidados de Saúde , Pediatria , Fatores de Risco